York YZB018 THRU 060 User Manual
Page 39

271457-YTG-B-0908
Johnson Controls Unitary Products
39
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
OUTDOOR UNIT MODEL NO.
YZB04811
INDOOR COIL MODEL NO.
FC/MC/PC/UC60
AIR TEMP.
ENTERING
OUTDOOR UNIT
AIR TEMP.
ENTERING
INDOOR COIL
ID CFM
1400
1600
1800
MBTUH
KW
C.O.P.
MBTUH
KW
C.O.P.
MBTUH
KW
C.O.P.
60
60
59.1
4.9
3.6
59.6
4.7
3.7
60.2
4.5
3.9
70
61.4
4.4
4.1
61.9
4.2
4.3
62.4
4.1
4.5
80
63.7
4.0
4.7
64.1
3.8
4.9
64.6
3.7
5.2
47
60
47.3
3.9
3.6
49.6
3.9
3.7
51.8
3.9
3.9
70
49.4
4.3
3.3
51.0
4.3
3.5
52.6
4.2
3.7
80
51.5
4.8
3.2
52.4
4.6
3.3
53.3
4.5
3.5
40
60
48.4
4.0
3.6
49.2
3.8
3.8
49.9
3.7
3.9
70
44.4
4.3
3.0
45.1
4.2
3.1
45.9
4.1
3.2
80
40.3
4.6
2.6
41.1
4.6
2.6
41.8
4.6
2.7
30
60
36.4
3.8
2.8
39.7
3.8
3.1
42.9
3.8
3.4
70
33.4
4.2
2.4
36.5
4.2
2.6
39.6
4.2
2.8
80
30.5
4.6
2.0
33.4
4.6
2.1
36.3
4.6
2.3
17
60
37.0
4.0
2.7
36.1
3.9
2.7
35.2
3.8
2.7
70
34.4
4.4
2.3
33.2
4.2
2.3
32.0
4.1
2.3
80
31.8
4.8
2.0
30.3
4.6
1.9
28.8
4.4
1.9
10
60
32.1
3.9
2.4
31.1
3.8
2.4
30.2
3.8
2.4
70
28.3
4.3
1.9
28.1
4.2
1.9
28.0
4.2
2.0
80
24.6
4.7
1.5
25.2
4.6
1.6
25.7
4.6
1.7
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler
Coil
MBH
KW
COP
MA16C
FC60C
1.00
0.96
1.00
MA20D
FC/MC60D
1.00
0.96
1.00
MA20D
MC61D
1.00
0.96
1.00
MV16C
FC/MC60C
1.00
0.94
1.00
MV20D
FC/MC60D
1.00
0.94
1.00
MV20D
MC61D
1.00
0.94
1.00
AHP/SHP48
–
1.00
0.96
1.00
AHP/SHP60
–
1.00
0.96
1.00
AV/SV48
–
1.00
0.92
1.03
F*FV060
–
1.00
0.99
1.00
–
HC60
1.00
0.96
1.00
–
HD60
1.00
0.96
1.00
–
MC61
1.00
0.96
1.00
Variable Speed
Furnace
Coil
MBH
KW
COP
PV8*C20
FC/PC60C
1.00
0.94
1.00
PV8*C20
HC60
1.00
0.94
1.00
PV8*C20
HD60
1.00
0.94
1.00
P(C,V)9*C20
FC/PC60C
1.00
0.93
1.00
P(C,V)9*D20
FC/MC/PC60D
1.00
0.93
1.01
P(C,V)9*D20
HC60
1.00
0.94
1.00
P(C,V)9*D20
HD60
1.00
0.94
1.00
P(C,V)9*D20
MC61D
1.00
0.93
1.01
Y*9C*D20 FC/MC/PC60D
0.99
1.00
1.00
Y*9C*D20
FC/MC62D
1.00 1.01 0.98
Y*(8,L)C*C16
FC/PC60C
0.99 1.00 0.99
Y*(8,L)C*C20
FC/PC60C
0.99 1.01 0.97
Y*9C*C16
FC/PC60C
0.99 0.99 1.00
Y*9C*C20
FC/PC60C
0.99 0.99 1.00
Y*(8,L)C*C16
HD60
0.98 0.94 1.04
Y*(8,L)C*C20
HD60
0.97 0.95 1.03
Y*9C*C16
HD60
0.98 0.93 1.05
Y*9C*C20
HD60
0.98 0.93 1.05
Y*9C*D20
HD60
0.98 0.94 1.05
Y*(8,L)C*C16
UC60C
0.99 1.02 0.98
Y*(8,L)C*C20
UC60C
0.99 1.03 0.96
Y*9C*C16
UC60C
1.00 1.01 0.99
Y*9C*C20
UC60C
1.00 1.01 0.99
Y*9C*D20
UC60D
1.00 1.01 0.98
G*9V*D20
FC/MC/PC60D
0.99 1.00 1.00
G*9V*D20
FC/MC62D
1.00 1.01 0.98
G*9V*C16
FC/PC60C
0.99 0.99 1.00
G*9V*C20
FC/PC60C
0.99 0.99 1.00
G*9V*C16
HD60
0.98 0.93 1.05
G*9V*C20
HD60
0.98 0.93 1.05
G*9V*D20
HD60
0.98 0.94 1.05
G*9V*C16
UC60C
1.00 1.01 0.99
G*9V*C20
UC60C
1.00 1.01 0.99
G*9V*D20
UC60D
1.00 1.01 0.98
Variable Speed
Furnace
Coil
MBH
KW
COP