CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
Y*(8,L)C*C20
FC/MC/PC48C 35.4 3.58 2.90 23.8 2.46 2.84 8.20
Y*9C*C16
FC/MC/PC48C 35.6 3.52 2.96 24.0 2.42 2.91 8.20
Y*9C*C20
FC/MC/PC48C 36.0 3.54 2.98 24.2 2.42 2.93 8.20
Y*(8,L)C*C16
HC42
35.4 3.50 2.96 23.8 2.42 2.88 8.20
Y*(8,L)C*C20
HC42
35.4 3.54 2.93 23.8 2.44 2.86 8.20
Y*9C*C16
HC42
35.6 3.46 3.02 24.0 2.38 2.96 8.10
Y*9C*C20
HC42
35.4 3.50 2.96 24.0 2.42 2.91 8.20
Y*(8,L)C*B12
HD48
34.8 3.10 3.29 23.8 2.10 3.32 7.90
Y*(8,L)C*C16
HD48
34.6 3.16 3.21 23.4 2.14 3.20 8.00
Y*(8,L)C*C20
HD48
34.6 3.18 3.19 23.4 2.14 3.20 8.00
Y*9C*B12
HD48
35.0 3.10 3.31 23.8 2.10 3.32 7.90
Y*9C*C16
HD48
34.8 3.14 3.25 23.6 2.12 3.26 7.90
Y*9C*C20
HD48
35.2 3.20 3.22 24.2 2.18 3.25 7.90
Y*(8,L)C*A12
UC36A
35.4 3.24 3.20 24.8 2.24 3.24 8.00
Y*(8,L)C*B12
UC36B
35.2 3.26 3.16 24.6 2.26 3.19 8.00
Y*9C*B12
UC36B
35.2 3.28 3.15 24.6 2.28 3.16 8.00
Y*(8,L)C*C16
UC36C
35.2 3.34 3.09 23.8 2.32 3.01 8.10
Y*(8,L)C*C20
UC36C
35.0 3.36 3.05 23.8 2.32 3.01 8.10
Y*9C*C16
UC36C
35.2 3.36 3.07 23.8 2.32 3.01 8.10
Y*9C*C20
UC36C
35.6 3.34 3.12 23.8 2.26 3.09 8.00
Y*(8,L)C*C16
UC48C
35.6 3.66 2.85 24.0 2.52 2.79 8.30
Y*(8,L)C*C20
UC48C
35.6 3.68 2.84 23.8 2.54 2.75 8.30
Y*9C*C16
UC48C
35.8 3.62 2.90 24.0 2.50 2.81 8.20
Y*9C*C20
UC48C
36.2 3.64 2.91 24.4 2.48 2.88 8.20
G*9V*B12
FC/MC/PC35B 35.4 3.30 3.14 24.0 2.30 3.06 8.00
G*9V*C16
FC/MC/PC35C 35.4 3.38 3.07 24.4 2.36 3.03 8.10
G*9V*C20
FC/MC/PC35C 35.8 3.38 3.10 23.8 2.30 3.03 8.10
G*9V*A12
FC/MC/PC36A 35.6 3.28 3.18 24.2 2.30 3.08 8.00
G*9V*B12
FC/MC/PC36B 35.4 3.34 3.11 24.4 2.36 3.03 8.00
G*9V*C16
FC/MC/PC36C 35.2 3.42 3.02 24.4 2.40 2.98 8.10
G*9V*C20
FC/MC/PC36C 35.6 3.42 3.05 23.6 2.32 2.98 8.10
G*9V*A12
FC/MC/PC37A 35.6 3.32 3.14 24.6 2.34 3.08 8.00
G*9V*B12
FC/MC/PC43B 35.8 3.42 3.07 24.2 2.36 3.01 8.10
G*9V*C16
FC/MC/PC43C 35.6 3.46 3.02 24.0 2.38 2.96 8.10
G*9V*C20
FC/MC/PC43C 35.4 3.50 2.96 24.0 2.42 2.91 8.20
G*9V*C16
FC/MC/PC48C 35.6 3.52 2.96 24.0 2.42 2.91 8.20
G*9V*C20
FC/MC/PC48C 36.0 3.54 2.98 24.2 2.42 2.93 8.20
G*9V*C16
HC42
35.6 3.46 3.02 24.0 2.38 2.96 8.10
G*9V*C20
HC42
35.4 3.50 2.96 24.0 2.42 2.91 8.20
G*9V*B12
HD48
35.0 3.10 3.31 23.8 2.10 3.32 7.90
G*9V*C16
HD48
34.8 3.14 3.25 23.6 2.12 3.26 7.90
G*9V*C20
HD48
35.2 3.20 3.22 24.2 2.18 3.25 7.90
G*9V*A12
UC36A
35.6 3.22 3.24 24.8 2.24 3.24 7.90
G*9V*B12
UC36B
35.2 3.28 3.15 24.6 2.28 3.16 8.00
G*9V*C16
UC36C
35.2 3.36 3.07 23.8 2.32 3.01 8.10
G*9V*C20
UC36C
35.6 3.34 3.12 23.8 2.26 3.09 8.00
G*9V*C16
UC48C
35.8 3.62 2.90 24.0 2.50 2.81 8.20
G*9V*C20
UC48C
36.2 3.64 2.91 24.4 2.48 2.88 8.20
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.
HEATING CAPACITY - YZB03611With Variable Speed Furnaces (Continued)
VARIABLE
SPEED
FURNACE
COIL
1
MODEL
ARI HEATING
2
47
°F
17
°F
HSPF
MBH
COP
KW
MBH
COP
KW
STD