beautypg.com

York YZB018 THRU 060 User Manual

Page 12

background image

271457-YTG-B-0908

12

Johnson Controls Unitary Products

COOLING CAPACITY - YZB04811With Variable Speed Furnaces

VARIABLE SPEED

FURNACE MODEL

COIL

MODEL

1

W

COOLING

RATED

CFM

NET MBH

SEER

EER

TOTAL

SENS.

1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES

2

P(C,V)9*D20

FC/MC/PC60D

24

1600

46.0

32.2

13.25

11.00

P(C,V)9*D20

MC61D

24

1600

46.5

32.6

13.25

11.00

Y*9C*D20 FC/MC/PC60D

24

1615

47.0

35.8

13.40

11.50

Y*9C*D20 FC/MC62D

24

1630

47.5

36.2

13.40

11.50

Y*(8,L)C*C16 FC/PC60C

21

1625

47.5

36.0

13.60

11.60

Y*(8,L)C*C20 FC/PC60C

21

1605

47.5

36.2

13.90

11.80

Y*9C*C16 FC/PC60C

21

1590

47.0

35.8

13.40

11.40

Y*9C*C20 FC/PC60C

21

1655

47.0

35.8

13.40

11.40

Y*(8,L)C*C16 HD60

21

1625

47.0

35.6

13.50

11.50

Y*(8,L)C*C20 HD60

21

1605

47.5

35.8

13.70

11.80

Y*9C*C16 HD60

21

1590

47.0

35.4

13.20

11.40

Y*9C*C20 HD60

21

1655

47.0

35.4

13.20

11.40

Y*9C*D20 HD60

24

1615

47.0

35.6

13.40

11.50

Y*(8,L)C*C16 UC60C

21

1625

46.5

35.0

13.40

11.40

Y*(8,L)C*C20 UC60C

21

1605

47.0

35.2

13.60

11.70

Y*9C*C16 UC60C

21

1590

46.5

35.0

13.10

11.30

Y*9C*C20 UC60C

21

1655

46.5

35.0

13.10

11.30

Y*9C*D20 UC60D

24

1615

46.5

34.8

13.30

11.40

G*9V*D20 FC/MC/PC60D

24

1615

47.0

35.8

13.40

11.50

G*9V*D20 FC/MC62D

24

1630

47.5

36.2

13.40

11.50

G*9V*C16 FC/PC60C

21

1590

47.0

35.8

13.40

11.40

G*9V*C20 FC/PC60C

21

1655

47.0

35.8

13.40

11.40

G*9V*C16 HD60

21

1590

47.0

35.4

13.20

11.40

G*9V*C20 HD60

21

1655

47.0

35.4

13.20

11.40

G*9V*D20 HD60

24

1615

47.0

35.6

13.40

11.50

G*9V*C16 UC60C

21

1590

46.5

35.0

13.10

11.30

G*9V*C20 UC60C

21

1655

46.5

35.0

13.10

11.30

G*9V*D20 UC60D

24

1615

46.5

34.8

13.30

11.40

1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Variable speed furnaces have B.O.D (Blower on Delay) standard.

COOLING CAPACITY - YZB06012With Variable Speed Furnaces

VARIABLE SPEED

FURNACE MODEL

COIL

MODEL

1

W

COOLING

RATED

CFM

NET MBH

SEER

EER

TOTAL

SENS.

1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES

2

P(C,V)9*D20

FC/MC62D

24

1620.0

54.0

40.5

13.5

11.0

Y*(8,L)C*C20 FC/MC62D

21

1615

56.0

40.5

13.60

11.50

Y*9C*C20 FC/MC62D

21

1655

55.5

40.0

13.20

11.10

Y*9C*D20 FC/MC62D

24

1630

55.5

40.0

13.30

11.20

G*9V*C20 FC/MC62D

21

1655

55.5

40.0

13.20

11.10

G*9V*D20 FC/MC62D

24

1630

55.5

40.0

13.30

11.20

1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Variable speed furnaces have B.O.D (Blower on Delay) standard.