York YZB018 THRU 060 User Manual
Page 24

271457-YTG-B-0908
24
Johnson Controls Unitary Products
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
OUTDOOR UNIT MODEL NO.
YZB02411
INDOOR COIL MODEL NO.
AHP24
CONDENSER
ENTERING AIR
TEMPERATURE
ID CFM
600
800
1000
ID DB (°F)
80
80
75
80
80
80
80
75
80
80
80
80
75
80
80
ID WB (°F)
57
62
62
67
72
57
62
62
67
57
57
62
62
67
72
65
T.C.
21.7
24.5
23.6
27.4
29.9
24.0
25.4
24.8
28.4
30.8
26.4
26.3
26.0
29.5
31.7
S.C.
21.9
20.9
16.6
17.8
14.0
24.3
23.9
19.3
19.9
15.6
26.7
24.3
22.0
22.0
17.2
K.W.
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
75
T.C.
20.9
23.1
22.3
25.5
28.0
23.1
24.2
23.4
26.6
28.9
25.3
25.4
24.5
27.6
29.9
S.C.
21.1
19.9
15.9
16.6
13.3
23.4
22.8
18.3
18.9
14.8
25.6
25.7
20.8
21.2
16.4
K.W.
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
85
T.C.
20.2
21.7
21.1
23.6
26.1
22.2
23.1
22.0
24.7
27.1
24.3
24.5
23.0
25.8
28.1
S.C.
20.4
18.9
15.1
15.5
12.5
22.4
21.7
17.4
18.0
14.1
24.5
24.5
19.6
20.4
15.6
K.W.
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
95
T.C.
19.5
20.2
19.8
21.7
24.1
21.4
21.9
20.6
22.8
25.2
23.2
23.6
21.4
23.9
26.3
S.C.
19.6
17.9
14.4
14.3
11.8
21.5
20.6
16.4
17.0
13.3
23.4
23.3
18.5
19.7
14.8
K.W.
2.0
2.0
2.1
2.0
2.0
2.0
2.0
2.1
2.0
2.0
2.0
2.0
2.1
2.0
2.0
105
T.C.
18.1
18.7
18.3
20.1
22.6
19.8
20.2
19.0
21.1
23.6
21.5
21.8
19.7
22.0
24.5
S.C.
18.2
17.0
13.7
13.7
11.2
19.9
19.2
15.7
16.2
12.8
21.7
21.4
17.7
18.8
14.3
K.W.
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
115
T.C.
16.7
17.2
16.8
18.6
21.2
18.2
18.6
17.4
19.4
21.9
19.8
20.0
18.0
20.2
22.7
S.C.
16.8
16.1
13.0
13.0
10.7
18.4
17.8
15.0
15.4
12.2
20.0
19.5
17.0
17.9
13.8
K.W.
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
125
T.C.
15.3
15.7
15.3
17.1
19.7
16.7
17.0
15.8
17.7
20.3
18.1
18.3
16.3
18.4
20.9
S.C.
15.4
15.2
12.4
12.3
10.2
16.9
16.4
14.3
14.7
11.7
18.3
17.7
16.3
17.0
13.3
K.W.
3.0
3.1
3.1
3.1
3.0
3.0
3.1
3.1
3.1
3.0
3.0
3.1
3.1
3.1
3.0
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler
Coil
T.C.
S.C.
KW
MA08B
FC/MC24B
1.00
1.00
1.00
MA08B
FC/MC30B
1.00
1.00
1.00
MV12B
FC/MC24B
1.03
1.02
0.96
MV12B
FC/MC30B
1.03
1.02
0.96
AV24
–
1.03
1.02
0.96
F*FP030
–
1.00
1.00
1.00
–
FC/MC/PC/UC24
1.00
1.00
1.00
–
FC/MC/PC/UC30
1.00
1.00
1.00
–
HC30
1.00
1.00
1.00
–
HD24
0.98
1.06
1.00
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
PV8*A12
FC/MC/PC24A
1.00
0.96
1.03
PV9*A12
FC/MC/PC24A
1.00
0.96
1.07
PV8*A12
FC/MC/PC30A
1.00
0.96
1.03
PV9*A12
FC/MC/PC30A
1.00
0.96
1.07
Y*(8,L)C*A12
FC/MC/PC24A
1.02 1.05 0.92
Y*(8,L)C*B12
FC/MC/PC24B
1.02 1.05 0.91
Y*9C*B12
FC/MC/PC24B
1.02 1.05 0.93
Y*(8,L)C*A12
FC/MC/PC30A
1.02 1.05 0.92
Y*(8,L)C*B12
FC/MC/PC30B
1.02 1.05 0.91
Y*9C*B12
FC/MC/PC30B
1.02 1.05 0.93
Y*(8,L)C*A12
FC/MC/PC32A
1.02 1.04 0.93
Y*(8,L)C*A12
HC30
1.02 1.02 0.93
Y*(8,L)C*A12
HD24
1.04 1.06 0.93
Y*(8,L)C*B12
HD24
1.04 1.06 0.92
Y*9C*B12
HD24
1.04 1.06 0.93
Y*(8,L)C*A12
UC24A
1.04 1.05 0.93
Y*(8,L)C*B12
UC24B
1.04 1.06 0.92
Y*9C*B12
UC24B
1.03 1.05 0.93
Y*(8,L)C*A12
UC30A
1.04 1.05 0.93
Y*(8,L)C*B12
UC30B
1.04 1.06 0.92
Y*9C*B12
UC30B
1.03 1.05 0.93
G*9V*A12
FC/MC/PC24A
1.02 1.04 0.94
G*9V*B12
FC/MC/PC24B
1.02 1.05 0.93
G*9V*A12
FC/MC/PC30A
1.02 1.04 0.94
G*9V*B12
FC/MC/PC30B
1.02 1.05 0.93
G*9V*A12
FC/MC/PC32A
1.02 1.04 0.96
G*9V*A12
HC30
1.02 1.04 0.94
G*9V*A12
HD24
1.03 1.05 0.94
G*9V*B12
HD24
1.04 1.06 0.93
G*9V*A12
UC24A
1.03 1.04 0.94
G*9V*B12
UC24B
1.03 1.05 0.93
G*9V*A12
UC30A
1.03 1.04 0.94
G*9V*B12
UC30B
1.03 1.05 0.93
Variable Speed
Furnace
Coil
T.C.
S.C.
KW