108 Status Registers & Result Codes
Command bit dec hex Function and description
Ref.
power on
64
40
Profile 2 as active settings after
power on
Z2
96
60
Profile 3 as active settings after
power on
Z3
128 80 * Factory default as active settings
after power on
Z4
S16=
dec hex Test status register
+000
0
0
No test in progress
&T0
1
1
Loop-back test in progress
&T1
3
3
Local Digital Loop-back test in
process
&T3
6
6
Remote Digital Loop-back test
in process
&T6
7
7
Remote Digital Loop-back with
self-test in process
&T7
8
8
Analog Loop-back with self test
in progress
&T8
S17=
bit dec hex Bit-mapped register
+018
0
0
0
Disable secondary channel
(default)
*S0
4-1 0-30 0-1E Set leased line transmit power
level from 0 to -15 dBm. (See
also S35b3) (Default *P9)
*Pn
5
0
0
Normal dial (Default)
D
32
20
Reverse dial, go on-line in
answer mode.
DR
7,6 0
0
AT Commands set (Default)
*I0
64
40
V.25bis command set
*I1
128 80
Dumb mode (no command
*I2