beautypg.com

Callback security -11 – Western Telematic AFS-16-1 User Manual

Page 32

background image

5-11

Basic Configuration

To erase log data, access command mode via the Text Interface, using an account that
permits Administrator level commands, then type

/L and press [Enter] to access the

Display Logs menu and then proceed as follows:

Audit Log: At the Display Logs menu, type

1 and then press [Enter]. When the

Audit Log appears, type

E and press [Enter] to erases the Audit Log.

Alarm Log: At the Display Logs menu, type

2 and then press [Enter]. When the

Alarm Log appears, type

E and press [Enter] to erase the Alarm Log.

Temperature Log: At the Display Logs menu, type

3 and press [Enter]. When the

Temperature Log menu appears, type

E and press [Enter] to erase the

Temperature Log.

Notes:

• The AFS-16 dedicates a fixed amount of internal memory for Audit Log

records, and if log records are allowed to accumulate until this memory
is filled, memory will eventually "wrap around," and older records will be
overwritten by newer records.

• Note that once records have been erased, they cannot be recovered.

5.3.4. Callback Security
The Callback function provides an additional layer of security when callers attempt to
access command mode via modem. When this function is properly configured, modem
users will not be granted immediate access to command mode upon entering a valid
password; instead, the unit will disconnect, and dial a user-defined number before
allowing access via that number. If desired, users may also be required to re-enter the
password after the AFS-16 dials back.

In order for Callback Security to function properly, you must first enable and configure
the feature as described in this section, and then define a callback number for each
desired user account as described in Section 5.5. To access the Callback Security
menu via the Text Interface, type

/F and press [Enter] and then select the Callback

Security option. To access the Callback Security menu via the Web Browser Interface,
place the cursor over the General Parameters link, wait for the flyout menu to appear,
and then Click on the "Callback Security" link.