Basic Configuration
• Log Configuration: In the Text Interface, this item provides access to a submenu
which is used to configure the Audit Log, Alarm Log and Temperature Log as
described in Section 5.3.3. In the Web Browser Interface, these parameters are
directly accessed via the System Parameters menu.
Audit Log: When enabled, the Audit Log will create a record of all A/B switching
at the AFS-16 unit, including switching that was initiated by alarms.
(Default = On without Syslog.)
Alarm Log: When enabled, the Alarm Log will create a record of all alarm activity
at the AFS-16 unit. (Default = On without Syslog.)
Temperature Log: When enabled, the Temperature Log will create a record of
temperature vs. time at the AFS-16 unit. (Default = On.).
• Callback Security: Enables and configures the Callback Security Function as
described in Section 5.3.4. In order for this feature to function, a Callback number
must also be defined for each desired user account as described in Section 5.5.
(Default = On - Callback without Password Prompt, 3 attempts, 30 Minute Delay.)
Notes:
• In the Text Interface, Callback Security Parameters are defined via a submenu
of the Systems Parameters Menu, which is accessed via the Callback
Security item.
• In the Web Browser Interface, Callback Security Parameters are defined via a
separate menu, which is accessed by clicking the "Callback Security" link on
the left hand side of the screen.
• Control Card A/B Switch: This item can be used to enable/disable the Master A/B
Gang Switch on the AFS-16 Control Module. (Default = On.)
• Control Card Reset Switch: This item can be used to enable/disable the Reset
Switch on the AFS-16 Control Module. (Default = On.)
• Modem Phone Number: When an optional external modem is connected to the
AFS-16 Control Card's RS232 Port, the Modem Phone Number parameter can be
used to denote the phone number for the external modem. (Default = undefined.)
• Management Utility: Enables/Disables the Management Utility. When enabled,
the Management Utility allows you to manage multiple WTI units via a single menu.
For more information on the Management Utility, please refer to the Management
Utility User's Guide on the CDROM included with the unit. (Default = Off.)
Note: Although the Management Utility can be enabled/disabled via either the
Web Browser Interface and Text Interface, the Management Utility can only be
accessed and operated via the Web Browser Interface.
• Scripting Options: Provides access to a submenu that is used to configure
the Command Confirmation and Automated Mode parameters as described in
Section 5.3.5.
Note: In the Text Interface, the Scripting Options submenu is accessed via
item 13. To access the Scripting Options parameters via the Web Browser
Interface, place the cursor over the "General Parameters" link, wait for the flyout
menu to appear, then click on the "Scripting Options" link.