beautypg.com

Toshiba B-570 SERIES User Manual

Page 64

background image

2-3

EM18-33010A

2. MAJOR UNIT REPLACEMENT

CAUTION:

Be careful when replacing the CPU PC board, since a non-resettable counter (IC12) is installed on
this board. (Refer to Section 6.2.1 Maintenance Counter Printing.)

If this counter should be reset, replace IC12.

Fig. 2-4

Fig. 2-5

(Revision Date: Feb. 10, 2000)

2.1 REPLACING THE PS UNIT, I/F PC BOARD AND CPU PC BOARD

6) Adjust the ribbon end sensor.

Use the following Ribbons; TTM-78 (Maker: Fujicopian)

1

Set the ribbon so that the ribbon end sensor
can detect the ribbon. Turn the power on.

2

Turn the VR1 so that the voltage between Pin
1 (GND) and Pin 7 of CN12 is 3.0

±

0.2 V with

an oscilloscope.

3

Turn the power off and mount the left side
cover and top cover.

7) Adjust the black mark sensor.

As the black mark sensor is adjusted by key entries in system mode, refer to page 6-39 for the
adjustment procedure.

8) Adjust the feed gap sensor.

As the feed gap sensor is adjusted by key entries in system mode, refer to page 6-40 for the
adjustment procedure.

CN7

CN8

CN9

VR1

CN10

1

13

CN12

IC28

IC25

IC23

Range : 1V / 0.2 m sec.

Voltage

3.0 0.2V

VR1

GND