6-34

EM18-33010A

6. DIAG. TEST OPERATION

6.3.14 Threshold Manual Fine Adjustment for the Feed Gap Sensor

NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables

a fast forward.

2. A changed threshold fine adjustment value is stored in memory by pressing the

[PAUSE] key.

3. The above operations do not require any more threshold setting.

[FEED] key:
Pressing the [FEED] key onetime is a -0.1V
change, up to 0.0V

[RESTART] key:
Pressing the [RESTART] key onetime is a
+0.1V change, up to 4.0V.

Power off

Turn on the power while
holding down the [FEED]
key and [PAUSE] key.

Press the [PAUSE] key.

Press the [PAUSE] key sixteen times.

< 1

D I A G N O S T I C

V 1 . O A

>

< 2

P A R A M E T E R

S E T

>

T H

E S H O L D T

1 . 4 V

R

Press the [FEED] key or
[RESTART] key to fine
adjust the feed gap sensor
manual threshold.

Press the [FEED] key
and [RESTART] key at
the
same time.

Press the [PAUSE] key.

Continued on Section
6.3.15 Kanji Code
Selection.

(Revision Date: Dec. 10 ‘99)

6.3 PARAMETER SETTING MODE