6-40

EM18-33010A

6. DIAG. TEST OPERATION

(Revision Date: Dec. 10 ‘99)

6.3 PARAMETER SETTING MODE

6.3.18 Reset Selection when the INPUT • PRIME Signal is ON.

Reset ON/OFF when the INPUT • PRIME signal ON is selected.

NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enable.

2. A changed “Reset ON/OFF when the INPUT • PRIME signal is ON” is stored in memory by

pressing the [PAUSE] key.

Power off

Turn on the power while
holding down the [FEED]
key and [PAUSE] key.

Press the [FEED] key.

Press the [PAUSE] key 20 times.

Select the "Reset ON/OFF

when the INPUT • PRIME

signal is ON" with the [FEED] key

or [RESTART] key.

Press the [PAUSE] key.

• ON:

The printer will restore to the initial status.

• OFF: The printer will not restore to the initial status.

< 1

D I A G N

I C . V

>

1 . O A

O S T

< 2

P A R A M

R S E T

>

E T E

I N

U T P R

P

O N

I M E