Error Message Descriptions

B-3

invalid Vcc chosen – Retry, Abort

The V

CC

value you have chosen for your device is invalid.

Use a valid V

CC

value—0, 5, or 6 volts.

invalid VPP chosen – Retry, Abort

The V

PP

value you have chosen is invalid.

Use a valid V

PP

value—0, 5, 12, 12.5, or 21 volts.

unable to communicate with TMS370 device – Retry, Abort

The programmer is unable to communicate with the TMS370 microcon-
troller. The microcontroller may have bent pins, may be inserted incorrect-
ly, or may be inoperable. If you are using the gang programmer, a single
bad microcontroller can prevent the programmer from communication
with any of the devices.

Check each microcontroller for proper orientation or for bent pins.

unable to program after 25 attempts – Retry, Abort

The target EPROM location is bad.

Use a different location or replace the target device.

unable to read byte before timeout – Retry, Abort

The programmer is unable to communicate with the TMS370 microcon-
troller. The microcontroller may have bent pins, may be inserted incorrect-
ly, or may be inoperable. If you are using the gang programmer, a single
bad microcontroller can prevent the programmer from communication
with any of the devices.

Check each microcontroller for proper orientation or for bent pins.

unable to write byte – Retry, Abort

The EPROM is not erased, and the programmer is unable to program a 1,
because a 0 has already been burned into the same address.