Gatekeeper

Administrator Settings > Site Settings

E.1 Gateway Prefix

.

Alias prefix if

registered as a Gateway.

Current Status

.

Displays the status

of Content Server registration with the
gatekeeper. (Registered or not registered).

Enabled

.

Choose Enabled to attempt

registration with the Gatekeeper.

Gatekeeper Discovery

.

Gatekeeper

Discovery configuration can be set to
MANUAL or AUTO.

Manual

– The system will use a specific

gatekeeper identified by Gatekeeper IP
address.

Auto

– The system will automatically try

to register on any available gatekeeper.
If a gatekeeper responds to the request
sent from the codec within 30 seconds
this specific gatekeeper will be used.
This requires auto discovery on the
gatekeeper as well. If no gatekeeper
responds, the system will not use a
gatekeeper for making H.323 calls and
hence an IP address must be specified

IP Address

.

This gatekeeper IP-address

will be used if you specify Gatekeeper
Discovery: Manual.

Port

.

This port setting should not be

changed unless the local network
configuration specifies a different port.

Registration

.

Choose to register the Content

Server as a Terminal or as a Gateway.

H. Gateway Prefix

.

Alias prefix if

registered as a Gateway.

Restart Service

.

Restart Service will terminate calls that are currently live (that is, the

calls will be ended and conferences will not be available for on demand playback).
Before restarting the Service, check if there are live conferences in progress in the
Live Conferences page or check the call status on the LCD panel of the unit. The Site
Settings page will also display a warning if calls are in progress. If you click on the

Restart Service

button while calls are in progress, you will be asked to confirm if you

want to go ahead with the Restart.