Toshiba LF516 User Manual
Page 45
44
6 F 8 A 0 9 3 4
○ Pulse output setting mode
This mode is used to perform continuous parameter settings (automatic operation) regarding
pulse outputs. When these parameters are set, pulse output is ready to send out.
(1) Digital Output 1 selection screen
The function for Digital Output 1 can be selected.
This screen shows functions related to pulse outputs only.
(For details of setting procedure, see 8.2.18.)
• PLS OUT (Pulse output)
• PLS FRD (Forward direction pulse output)
• PLS REV (Reverse direction pulse output)
(2) Count rate setting screen
Count rate can be set.
(For details of setting procedure, see 8.2.20.)
(3) Pulse width setting screen
When pulse width setting mode is MANUAL, the screen moves to Pulse width setting screen.
When pulse width setting mode is AUTO, the screen moves to Totalizer control screen.
(For details of setting procedure, set See 8.2.20.)
Note: Pulse width setting mode is set to AUTO when shipped from the factory.
(4) Counter control screen
This screen is used to start the totalizer.
If is pushed, the screen returns to the measurement screen. (End of pulse output
setting mode)
(For details of operation procedure, see Section 10.2.)
Note: If is pushed to return to the measurement screen while automatic screen
sequence in progress, the setting items entered so far are saved.
PLS SET
To Measurement mode
ESC
PLS MODE
=AUTO
PLS MODE
=MANUAL
* (L) indicates that you can hold
down the switch longer.