(3) The following is an example for one-shot pulse output.
Setting preset count:100
Input/Output signal time chart
Preset output goes ON when the count value exceeds the preset value of 100 and the preset output
goes OFF when its width reaches the set pulse width.
When the preset value exceeds 100, the preset value is changed to 200 (adding the preset count of 100
to the current preset value of 100).
Then, the preset output goes ON when the count value exceeds the preset value of 200, and the
preset output goes OFF when its width reaches the set pulse width.
When the preset value exceeds 200, the preset value is changed to 300 (adding the preset count of
100 to the current preset value of 200).
Totalizer flow counts
ON
OFF
Preset point output
0
For it takes the time set pulse width
from the output goes OFF
100
200