3 piping connections – Toshiba LF516 User Manual
Page 22
21
6 F 8 A 0 9 3 4
4.3 Piping Connections
(1) Required Pipe Length
If various joints are used upstream of the detector outlet, the straight pipe length
as shown in Table 4.2 is required.
Table 4.2 Required straight pipe length on the upstream side
L: Required straight pipe length—straight pipe length plus half length of the detector.
D: Nominal bore size (diameter)
NOTES
The length of a reducer, if connected, can be counted as a part of the straight pipe length.
No straight pipe length is needed on the downstream side. If a butterfly valve is installed downstream
of the detector, do not let the valve plate protrude into the pipe of the detector
L=5D L=10D
(1) 90 bent
(2) Tee
(3) Diffuser
(4) Fully opened sluice valve
(5) Other valves (not fully opened)
L
L
L
L
L