3 parameter initial settings list – Toshiba LF516 User Manual
Page 102
101
6 F 8 A 0 9 3 4
8.3 Parameter initial settings list
Unless otherwise specified, the default values for each parameter shown below are set when shipped from
the factory:
Parameter names
Default value
Excitation frequency
(*1)
Flow direction
NORMAL
Display 1
gal/min
Display 2
COUNT B
Display digit setting
(for Display 1 and Display 2)
1/1000
Custom coefficient
1.0
Custom unit
“ CUSTOM”(Head of character string is blank )
Range type
Single
Range 1
300 gal/min
Ranges 2 to 4
0 gal/min
Hysteresis 3.0
%
Damping constant
5.0 s
Rate-of-change limit
0.0 %
Control limit time
0.0 s
Low cutoff
1.0 %
Display low cutoff
LINEAR
Manual zero
0.0 %
4
−20mADC alarm output
4mA
Output low limit setting
4mA
Digital output 1
NO USE
Digital output 2
NO USE
DO1/DO2 active status
NormOPEN
Digital input
NO USE
DI detective level
H LEVEL
Count rate
100 gal
Pulse width setting mode
AUTO
Pulse width
5 ms
Preset count
00000000
Preset function
HOLD
High alarm On/Off
OFF
High alarm value
0.0 %
Low alarm On/Off
OFF
Low alarm value
0.0 %
High-High alarm On/Off
OFF
High-High alarm value
0.0 %
Low-Low alarm On/Off
OFF
Low-Low alarm value
0.0 %
Empty pipe alarm
NORMAL
Self-diagnosis On/Off
ON
Converter alarm
CONV ONLY
Fixed value output
OFF
Fixed value current
4mA
Fixed value pulse
0 pps
Password 000
LCD density adjustment
3
Switch position setting
BOTTOM
*1: See the setting values for each meter size in the table below.