beautypg.com

Toshiba LF516 User Manual

Page 130

background image


129

6 F 8 A 0 9 3 4

(2) Span setting

Setting of 8.2.7 “Custom Coefficient Setting” and 8.2.8 “Custom Unit Setting” is applied to the
custom coefficient and unit same as (1)Display of flow rate.

Example : In the case of custom unit [dL(deciliter)/min].

Custom coefficient setting






Set the custom coefficient in accordance with 8.2.7 “Custom Coefficient

Setting”. Set the conversion coefficient from m

3

/min

unit to the custom

coefficient. In the case of dL/min, set 10000 that is the conversion coefficient
of dL from m

3

.

Custom unit setting






Set the custom unit in accordance with 8.2.8 “Custom Unit Setting”. Set the

character string of unit to the custom unit. In the case of this example, set ‘d’
‘L’ ‘/’ ‘m’ ‘i’ ‘n’. The rest of 1 character is blank space because the maximum
character number of the custom unit is 7.

Span

setting

Select the custom unit dL/min to the span unit in accordance with 8.2.9 “Span

(Range)”. When custom unit is selected, the new span value will be displayed
automatically based on the custom coefficient and custom unit.

This manual is related to the following products: