Toshiba LF516 User Manual
Page 40
39
6 F 8 A 0 9 3 4
Note 1: Totalized flow volume and totalized difference flow volume are displayed to the least
significant
digit of the set count rate.
(Example1)
When the count rate is 0.0001 m
3
:
When the measurement object flows through 0.0001(m
3
), inside counter counts 1.
Because inside counter is 8 digits at the maximum, the maximum of totalized flow
is 9999.999(m
3
). When inside counter exceeds the maximum, inside counter return
to 0, and continue totalization.
Inside counter(m
3
)
Max 8 digits
Totalized flow display(m
3
)
Max 8 digits (include decimal point)
0
000.0000 m
3
1
000.0001 m
3
1000
000.1000 m
3
1000000
100.0000 m
3
10000000
1000.000 m
3
99999999
9999.999 m
3
(Example2)
When the count rate is 10 m
3
:
When the measurement object flows through 10(m
3
), inside counter counts 1.
Because inside counter is 8 digits at the maximum, the maximum of totalized flow
is 99999999(m
3
). When inside counter exceeds the maximum, inside counter return
to 0, and continue totalization.
Inside counter(m
3
)
Max 8 digits
Totalized flow display(m
3
)
Max 8 digits (include decimal point)
0
00000000 m
3
1
00000010 m
3
1000
00010000 m
3
1000000
10000000 m
3
10000000
99999999 m
3
99999999
99999999 m
3
Note 2: Totalized difference flow volume shows the difference between the forward direction volume
and the reverse direction volume.
When the forward direction volume reaches the upper limit and returns to zero, the volume is
displayed as follows:
Forward direction volume: 1000
Reverse direction volume: -100
Difference flow volume:
900
99999999
-100
99999899
0
-100
-100