beautypg.com

Fault relay alarm – Transition Networks SISGM1040-162D User Manual

Page 68

background image

Transition Networks

SISGM1040-162D-LR

Technical Support: 1-800-260-1312

International: 00-1-952-941-7600

61

Fault Relay Alarm

The Fault Relay Alarm function provides the mechanism for warning when power or port

faults are detected. There is a set of relay contacts in the switch, and the contacts are

closed when either no fault alarms are configured, or the system is normal. With the

check boxes unchecked, the system won’t change the status of the relay when a fault

occurs. Please see the segment of ‘Wiring the Fault Alarm Contact’ for reference. With

both power input 1 and power input 2 installed and the check boxes of power 1/power 2

ticked, the FAULT LED indicator will then be possible to light up when any one of the

power fault occurs. As for the Port Link Down/Broken detection, the FAULT LED

indicator will light up when the port fault occurs.

Power Failure: Tick the check box to enable the function of lighting up the FAULT

LED on the panel when power fails.

Port Link Down/Broken: Tick the check box to enable the function of lighting up

FAULT LED on the panel when Ports’ states are link down or broken.

Fault Relay Alarm interface