Replacing Consumables and Maintenance Kit
20
1
GGGG
Holding the green handle, pull
up the Fusing Unit slowly in the
direction of the arrow, and then
put it in a stable and level place.
HHHH
Take out the new Fusing Unit
from the bag and put it in a stable
and level place.
Important
❒ The A3 paper which comes with
the new Fusing Unit will be
used in a later step
T
, so be care-
ful not to lose it.
❒ Do not turn the blue dial at the
side of the new fusing unit
when replacing it or before
turning on the power switch.
IIII
Remove the Fuser Oil Unit in the
direction of the arrow.
Important
❒ Do not touch inside of the Fus-
ing Unit.
❒ Be careful not to touch the oil.
JJJJ
Match (
U
U
U
U) on the front of the Fus-
er Oil Unit and the arrow on the
Fusing Unit as shown in the illus-
tration.
Important
❒ Be careful not to get oil on the
metal point of the left side of the
Fuser Oil Unit.
KKKK
Insert the left and right protru-
sions of the Fuser Oil Unit into
the white holders of the Fusing
Unit (
A
A
A
A), and then move the Fus-
er Oil Unit in the direction shown
by the arrow (
B
B
B
B) to attach the Fus-
er Oil Unit to the Fusing Unit.
LLLL
Put the removed Fuser Oil Unit in
the bag that enclosed the new
Fusing Unit, and then seal it.
ZDJH208J