Replacing Consumables and Maintenance Kit

16

1

FFFF

Lift the inner cover until it clicks
into place and holds.

The Development Unit is installed
shown in the illustration. Starting
from the upper left, the units are
attached in the order of black (K),
yellow (Y), cyan (C), and magenta
(M).

GGGG

Remove the Development Unit.
The procedure for removing the
unit is the same for all four colors.
A Hook your finger on the green

tab in front of the Develop-
ment Unit you want to replace,
and pull it out halfway.

Important

❒ Pulling out the Development

Unit quickly might cause it to
drop.

B Hold the right side of the De-

velopment Unit with your
right hand, and pull out the
unit slowly.

Important

❒ Be careful not to touch the

right side of the Photocon-
ductor Unit.

❒ Be careful not to let it get in

contact with your hands or
clothes.

HHHH

Install a new Development Unit.
The procedure for attaching the
Development Unit is the same for
all four colors.
A Take the unit out from the bag.

ZDJH016J

ZDJH046J

ZDJH225J

ZDJH993J

ZDJH226J

JupP1k_GB_Mainte_F_FM.book Page 16 Thursday, August 22, 2002 4:23 PM