Ni 73xx arc move limitations, Ni 73 xx arc move limitations -13, Ni 73 xx arc move limitations – National Instruments NI-Motion User Manual
Page 54

Chapter 4
What You Need to Know about Moves
© National Instruments Corporation
4-13
NI 73xx Arc Move Limitations
The following are limitations to the velocity and acceleration of arc moves.
Arc moves must use the following equations or an
NIMC_invalidVelocityError
is generated:
and
where
V = Velocity in counts/s
P = PID sample rate in seconds
I = Arc Interval (10 ms or 20 ms) in seconds
R = Radius in counts
Arc moves must use the following equations or an
NIMC_invalidAccelerationError
is generated:
and
where
P = PID sample rate in seconds
I = Arc Interval (10 ms or 20 ms) in seconds
R = Radius in counts
A = Acceleration/deceleration in counts/s
2
V P
×
4 R
≥
×
1,677,216
V P
2
Ч
83,443
Ч
(
)
R I
×
-------------------------------------------
16
≥
≥
A P
×
4 R
≥
×
65,536
A P
3
Ч
83,443
Ч
R I
2
Ч
--------------------------------------
1
≥
≥