National Instruments NI-Motion User Manual
Page 197

Chapter 13
Torque Control
© National Instruments Corporation
13-7
}
}while (!moveComplete && !(axisStatus &
NIMC_FOLLOWING_ERROR_BIT) && !(axisStatus &
NIMC_AXIS_OFF_BIT));
//Exit on move complete/following error/axis off
return
;// Exit the Application
///////////////////////////////////////////////////
// Error Handling
//
nimcHandleError; //NIMCCATCHTHIS:
// Check to see if there were any Modal Errors
if
(csr & NIMC_MODAL_ERROR_MSG){
do
{
//Get the command ID, resource ID, and the
error code of the //modal error from the
error stack on the device
flex_read_error_msg_rtn
(boardID,&commandI
D,&resourceID, &errorCode);
nimcDisplayError(errorCode,commandID,res
ourceID);
//Read the communication status register
flex_read_csr_rtn
(boardID,&csr);
}while(csr & NIMC_MODAL_ERROR_MSG);
}
else
// Display regular error
nimcDisplayError(err,0,0);
return
;// Exit the Application
}