Settings, Overview, I/o access functionality – Perle Systems 5500161-40 User Manual

Page 246: Field descriptions

background image

Settings

246

IOLAN SDS/SCS/STS/MDC User’s Guide, Version 4.0

Settings

Overview

The

I/O Interfaces Settings

window configures the parameters that are global to all I/O channels.

I/O Access Functionality

Field Descriptions

Configure the following parameters:

Enable I/O Access
to Modbus protocol

Enables/disables Modbus as the communication protocol for all the I/O
channels.

Default: Disabled

UID

This is the UID you are assigning to the IOLAN, which is acting as a Modbus
slave.

Default: 255

Advanced Modbus
Settings Button

Click this button to configure global Modbus Slave settings.

See

Advanced Slave Modbus Settings on page 247

for field descriptions.

Allow Modbus TCP
Application (API)

Allows a host running a Modbus/TCP application to communicate to the I/O
channels using the standard Modbus API.

Default: Permanently enabled when

Enable I/O Access via Modbus protocol

is enabled

See

Modbus I/O Access on page 278

for function codes and I/O

coil/registration descriptions.

Allow Modbus
RTU/ASCII via
TruePort

Enables/disables serial Modbus application access to the I/O over the network
using the TruePort COM redirector feature.

Default: Disabled

See

Modbus I/O Access on page 278

for function codes and I/O

coil/registration descriptions and

Accessing I/O Data Via TruePort on page

285

for the Perle API.