1 physical description, 2 environmental requirements, 3 ac power requirements – Psion Teklogix 9160 G2 User Manual
Page 283

Psion Teklogix 9160 G2 Wireless Gateway User Manual
261
Chapter 25: Specifications
Physical Description
Note:
Performance specifications are nominal and subject to change
without notice.
25.1 Physical Description
Enclosure:
Jet black in colour, FR2000 bay blend material
Dimensions:
< 30 x 20 x 12.5 cm (11.8 x 7.9 x 4.9 in.)
Weight:
< 2.25 kg (5.0 lbs.) (excludes radios, antennas,
and options)
25.2 Environmental Requirements
Operating Temperature: 0°C to 55°C (32°F to 131°F)
Operating Rel. Humidity: 10% to 90%
Storage Temperature:
0°C to 70°C (32°F to 158°F)
Dust and Rain:
IP42 or greater
Vibration:
EH0002 (Shipping vibration only)
Reliability:
MTBF 25,000 Hours (MIL-HDBK-217F)
25.3 AC Power Requirements
AC universal input via a standard IEC320 connector. Disables Power over
Ethernet (802.3af discovery) when connected.
Input voltage:
100 - 240 VAC nominal
Current:
5.0 A maximum
Warning:
A ground wire, not exceeding 3 m in length, must be connected
between the ground screw (located on the quick-release mount) and
a suitable earth ground bonding point on any 9160 G2 connected to
an antenna that is installed outdoors.