2 advanced entry calibration – Pitney Bowes J693 User Manual

Page 57

background image

J693

47

5.2.2

Advanced Entry Calibration


The second calibration method is the Advanced Entry Calibration. This method
overrides all previous calibration settings and should be used only when the
Standard Calibration method has failed.
The procedure has two parts:


1) Sensor Gain: Different algorithms are used for sampling, to produce

different measurements for the media.


2) Sensor Levels: At a selected gain, values are directly input for ‘Paper’,

‘Mark’ or ‘Gap’, and ‘Empty’ variables.


To perform an Advanced Entry Calibration:

Step

Operator Action

Displayed Message

Comment

1


Turn ‘On’ the printer.


"


2

Press the

key to enter

Menu Mode.


Raise the printhead
assembly for visual access
to the Media Sensor and
media.


"


See Section

4.0.2 for
details.

3


Press the

key to

enter the Media Settings
menu.


"

"


See Section

4.1.1 for
details.

4


Press the key.


"


See Section

4.1.1 for
details.

5


Press the key. Use
the key to scroll to
the desired sensor type and
press the

key to

enable the selection.


J"


See Section

4.1.1 for
details.


The enabled

selection will
be indicated
with an *

.

(Continued next page)