beautypg.com

4 system settings – Pitney Bowes J693 User Manual

Page 34

background image

24

J693

4.1.4

System Settings

INTERNAL MODULE

—

1024 KB

Sets the number of 1K blocks allocated for
the internal RAM ‘D’ module. Available
memory dependent upon model; see
Appendix C.

DEFAULT MODULE

—

D

Sets the default module used to store files
when no module is specified;

see Appendix C.

SCALEABLE FONT
CACHE

—

0312 KB

Sets the number of 1K blocks allocated for
the scaleable font engine. Available memory
dependent upon model; see Appendix C.

SYMBOL SET

Selects the code page used to print single
byte fonts unless otherwise specified in DPL,
see the Programmer’s Manual.

—

PC_850

MULTILINGUAL

61 selectable sets, see the Programmer’s
Manual.

TIME AND DATE

Allows the user to set Time and Date.

MEDIA COUNTERS

Internal record of inches printed and time in
use.

ABSOLUTE COUNTER

Shows the number of inches printed and
number of hours the printer has been
powered ‘On’ since being set at the factory.
Not resettable by the user.

RESETTABLE
COUNTER

The number of operational hours and inches
printed from the date last reset. User may
reset.

RESET COUNTER

Resets the resettable counters to zero.

PRINT CONFIGURATION

Prints the effective configuration of the
system. In addition, if settings were changed
that require a reset to become effective, this
will be indicated with the
‘§’ symbol.

A ‘

’ symbol next to the printed item

indicates that it was changed via the host but
not saved in non-volatile memory.

(Continued next page)