beautypg.com

6 diagnostics – Pitney Bowes J693 User Manual

Page 40

background image

30

J693

4.1.6

Diagnostics

HEX DUMP MODE

Most commonly used mode for trouble
shooting. Prints data and instructions
received from the host rather than
interpreting them (see Section 6.2).

ENABLE

Prints raw ASCII data received from the
host rather than executing the
commands.

—

DISABLE

Executes and prints label formats
(normal operating mode).

OPTIONS TESTING

Tests currently installed options

TEST PRESENT SENSOR

Performs a functional test of the Present
Sensor circuitry.

TEST CUTTER

Performs a functional test of the
optional cutter mechanism and circuitry.

PERFORM TEST
1 TIME

The cutter will cycle 1, 10 or 100 times
(user selects). The results of each
attempt will be displayed.

TEST

Tests the optional GPIO port, when
installed.

MONITOR GPIO INPUT

Performs a functional test of the GPIO
input circuitry.

MONITOR GPIO OUTPUT

Performs a functional test of the GPIO
output circuitry.

SENSOR READINGS

All Analog Sensor readings displayed

THR TRAN RIBM 24V->
255 255 255 255

Live sensor values may be viewed. View
is toggled with forward and reverse
keys. Maximum values are shown here:
thermistor sensor, transmissive (gap)
media sensor (TRAN is replaced with
REFL when SENSOR TYPE is set to
reflective), ribbon motion sensor, 24 volt
power supply sensor.

<- PS HD RANK
255 255 255

present sensor, head down, printhead
ranking resistor.

RIBBON

SENSOR LIMITS

Displays ribbon sensor ADC low and
high values. A Level 2 reset is required
to change these values.

RIBBON ADC LOW HIGH

070 104

Approximate default values are shown
here (actual values will vary).