4-8. E-Mail (SMTP) Setup

II Network Setup - Administrators only

60

Chapter 4 Setting from the Control Panel

E-Mail (SMTP) Setup (Part 2 of 2)

1

Use [

] or [

] to access to [E-Mail (SMTP) Setup] screen (2/2) from screen (1/2).

z

For details on the procedure for displaying the [Network setting] screen, refer to [4-2.Method for Setting Network from
Control Panel]
(

Page 23).

Connection Timeout

This function automatically stops the sending if communications bog down during data uploading to the
SMTP server and a certain period of time elapses.
[SMTP Timeout] sets this time value.

1

Touch the [EDIT] key on the [Connection Timeout] menu.
Each touch of the key will extend the timeout setting by 30 seconds, with a maximum value of 300
seconds.

Maximum Message Size

This sets the maximum capacity that the SMTP server can receive for one E-mail.

1

Touch the [000] digit key on the [Maximum Msg Size] menu.
Using the control panel, enter value between 0 and 100MB.

z

The factory set default setting is [0] (unlimited).

z

A message which exceeds the maximum message-size setting cannot be sent. Mail messages that have not been
sent are placed on the unsent mail list.