Issue 03/01

7 Specifications

MICROMASTER 411 & COMBIMASTER 411 Operating Instructions

6SE6400-5CA00-0BP0

95

7.2

Case Size Rating Information

Table 7-2

Case Size B

MICROMASTER 411 / COMBIMASTER 411

Frame size:
2 pole
4 pole

71
71

71
80

80
80

80M

90S

90S
90S

Motor Output Rating

0.37 kW

0,5 hp

0.55 kW

0,75 hp

0.75 kW

1,0 hp

1,1 kW

1,5 hp

1,5 kW

2,0 hp

Operating Input Voltage (rms)

3 AC 380 V – 480 V

±

10 %

Operating Input Frequency

47 – 63 Hz

Output Frequency
2 pole
4 pole

0 – 650 Hz

Inrush Current

< 4 A

Input Current (rms)

1,6 A

2,1 A

2,8 A

4,2 A

5,8 A

Output Current (max)

1,2 A

1,6 A

2,1 A

3,0 A

4,0 A

Power Supply fuse

10 A

Power Supply Lead
cross-section

4 mm

2

(max.)

Table 7-3

Case Size C

MICROMASTER 411 / COMBIMASTER 411

Frame size:
2- pole
4- pole

90L

100L

100L
100L

Motor Output Rating

2,2 kW

3,0 hp

3,0 kW

4,0 hp

Operating Input Voltage (rms)

3 AC 380 V – 480 V

±

10 %

Operating Input Frequency

47 – 63 Hz

Output Frequency
2 pole
4 pole

0 – 650 Hz

Inrush Current

< 7.7 A

Input Current (rms)

7,8 A

10 A

Output Current (max)

5,9 A

7,7 A

Power Supply fuse

16 A

Power Supply Lead
cross-section

4 mm

2

(max.)