2 case size rating information – Siemens MICROMASTER 411 User Manual
Page 95
Issue 03/01
7 Specifications
MICROMASTER 411 & COMBIMASTER 411 Operating Instructions
6SE6400-5CA00-0BP0
95
7.2
Case Size Rating Information
Table 7-2
Case Size B
MICROMASTER 411 / COMBIMASTER 411
Frame size:
2 pole
4 pole
71
71
71
80
80
80
80M
90S
90S
90S
Motor Output Rating
0.37 kW
0,5 hp
0.55 kW
0,75 hp
0.75 kW
1,0 hp
1,1 kW
1,5 hp
1,5 kW
2,0 hp
Operating Input Voltage (rms)
3 AC 380 V – 480 V
±
10 %
Operating Input Frequency
47 – 63 Hz
Output Frequency
2 pole
4 pole
0 – 650 Hz
Inrush Current
< 4 A
Input Current (rms)
1,6 A
2,1 A
2,8 A
4,2 A
5,8 A
Output Current (max)
1,2 A
1,6 A
2,1 A
3,0 A
4,0 A
Power Supply fuse
10 A
Power Supply Lead
cross-section
4 mm
2
(max.)
Table 7-3
Case Size C
MICROMASTER 411 / COMBIMASTER 411
Frame size:
2- pole
4- pole
90L
100L
100L
100L
Motor Output Rating
2,2 kW
3,0 hp
3,0 kW
4,0 hp
Operating Input Voltage (rms)
3 AC 380 V – 480 V
±
10 %
Operating Input Frequency
47 – 63 Hz
Output Frequency
2 pole
4 pole
0 – 650 Hz
Inrush Current
< 7.7 A
Input Current (rms)
7,8 A
10 A
Output Current (max)
5,9 A
7,7 A
Power Supply fuse
16 A
Power Supply Lead
cross-section
4 mm
2
(max.)