5 System Parameters
Issue 03/01
MICROMASTER 411 & COMBIMASTER 411 Operating Instructions
76
6SE6400-5CA00-0BP0
Communication (P0004 = 20)
ParNr ParText
Default
Acc
WS
QC
P0918 CB
address
3 2 CT
N
P0927
Parameter changeable via
15
2
CUT
N
r0965 Profibus
profile
- 3
- -
r0967 Control
word
1
- 3
- -
r0968
Status word 1
-
3
-
-
r0964[5]
Firmware version data
-
3
-
-
P0971
Transfer data from RAM to EEPROM
0
3
CUT
N
P2000[1] Reference
frequency
50.00 2 CT N
P2001[1] Reference
voltage
1000 3 CT N
P2002[1] Reference
current
0.10 3 CT N
P2009[2] USS
normalization
0
3 CT N
P2010[2] USS
baudrate
6
2 CUT
N
P2011[2] USS
address
0
2 CUT
N
P2012[2]
USS PZD length
2
3
CUT
N
P2013[2]
USS PKW length
127
3
CUT
N
P2014[2]
USS telegram off time
0
3
CT
N
r2015[4]
CO: PZD from BOP link (USS)
-
3
-
-
P2016[4]
CI: PZD to BOP link (USS)
52:0
3
CT
N
r2018[4]
CO: PZD from COM link (USS)
-
3
-
-
P2019[4]
CI: PZD to COM link (USS)
52:0
3
CT
N
r2024[2]
USS error-free telegrams
-
3
-
-
r2025[2]
USS rejected telegrams
-
3
-
-
r2026[2]
USS character frame error
-
3
-
-
r2027[2]
USS overrun error
-
3
-
-
r2028[2]
USS parity error
-
3
-
-
r2029[2]
USS start not identified
-
3
-
-
r2030[2]
USS BCC error
-
3
-
-
r2032
BO: CtrlWrd1 from BOP link (USS)
-
3
-
-
r2031[2]
USS length error
-
3
-
-
r2033
BO: CtrlWrd2 from BOP link (USS)
-
3
-
-
r2036
BO: CtrlWrd1 from COM link (USS)
-
3
-
-
r2037
BO: CtrlWrd2 from COM link (USS)
-
3
-
-
P2040
CB telegram off time
20
3
CT
N
P2041[5] CB
parameter
0
3 CT N
r2050[4]
CO: PZD from CB
-
3
-
-
P2051[4]
CI: PZD to CB
52:0
3
CT
N
r2053[5] CB
identification
-
3 - -
r2054[7] CB
diagnosis
-
3 - -
r2090
BO: Control word 1 from CB
-
3
-
-
r2091
BO: Control word 2 from CB
-
3
-
-