12 shock and vibration, 2 stress during operation (half sine shock), 3 vibration and shock stress during transport – Siemens MICROMASTER 411 User Manual
Page 147
Issue 03/01
10 Engineering Information
MICROMASTER 411 & COMBIMASTER 411 Operating Instructions
6SE6400-5CA00-0BP0
147
10.12
Shock and Vibration
The inverter has been tested for compliance with the following standards.
10.12.1 Vibration
Stress during Operation (Single Sine Sweep)
Required Standards:
EN 60721-3-3 class 3M6 and 3M8
Test standards:
EN60068-2-6, test Fc
Case Size B:
Class 3M6: 10-58 Hz/ 0.15 mm, 58-200 Hz/ 2g
Case Size C:
Class 3M6: 10-58 Hz/ 0.15 mm, 58-200 Hz/ 2g
10.12.2 Shock Stress during Operation (Half Sine Shock)
Required Standards:
EN 60721-3-3
Test standards:
EN 60068-2-27, test Ea
Case Size B:
Peak acceleration 5g - duration of shock 30 ms
Case Size C:
Peak acceleration 5g - duration of shock 30 ms
10.12.3 Vibration
and
Shock stress during Transport
Required Standards:
EN 60721-3-3
Test standards:
EN 60068-2-27, Test Ea
Class 2M2:
5-9 Hz/ 3.5 mm, 9-200 Hz/ 1g
Class 2M1:
Peak acceleration 15g - duration of shock 11 ms.
The inverter meets class 2M2 for Vibration stress and 2M1 for shock stress in
product packaging.