1 current monitoring accuracy – Siemens MICROMASTER 411 User Manual

Page 117

background image

Issue 03/01

10 Engineering Information

MICROMASTER 411 & COMBIMASTER 411 Operating Instructions

6SE6400-5CA00-0BP0

117

Figure 10-1 Current Limit Interaction

10.1.1 Current

Monitoring

Accuracy

Table 10-1 shows sample results comparing current measured with a current
scope, and the current displayed on the inverter, using measurements taken from a
variety of inverters at various switching frequencies, current loads, frequency
setpoints and cable lengths.

Table 10-1

Measured Current Monitoring Accuracy

Inverter

Frame Size B, 400 V
1,5 kW

Frame Size C, 400 V
3,0 kW

Switching frequency

4 kHz

4 kHz

Load on inverter

Nominal load

4 A

Nominal load

7,7 A

Frequency setpoint

45 Hz

45 Hz

Scope current (long cable)*

4,00 A

7,70 A

Drive current

4,05 A

7,46 A

% difference (inverter/scope)*

1,32 %

-3,9 %