beautypg.com

Sundance Spas ST201 User Manual

Page 60

background image

60

Sundance Technology

ST201

PRELIMINARY draft 2

RXEARLYTHRESH

Class....................I/O Registers, FIFO Control

Base Address ......IoBaseAddress register value

Address Offset .....0x3e

Access Mode .......Read/Write

Width ...................16 bits

The value stored in this register defines the number of bytes of the top of the frame that must be received
before a RxEarly interrupt will occur. The first byte of the destination address is considered to be byte 1.
The value in RxEarlyThresh may also determine how many bytes of a frame must be received before
RxDMA transfers for the frame are allowed to begin. If RxEarlyEnable in DMACtrl is set, a frame is not eli-
gible to start RxDMA until RxEarlyThresh bytes have been received.

RxEarlyThresh resets to the value

1ffch, which disables the threshold mechanism.

BIT

BIT NAME

BIT DESCRIPTION

12..0

RxEarlyThresh

The number of bytes which must be present in the RxFIFO before a
RxEarly interrupt is asserted. The minimum value is 0x08, any value
smaller than this will be interpreted as 0x08. Values greater than 0x08
will be interpreted using a resolution of 4 bytes (i.e. 0x08, 0x0c, 0x0f,
etc.)

15..13

Unused

These bits are ignored.