System specifications, Appendix a, Appendix a, system specifications – Juniper Networks ERX-1410 User Manual
Page 119: Ls of heat. see, Appendix a, system, Specifications, Specifications (see

A
System Specifications
Table A-1 ERX specifications
ERX-1400 Series
ERX-700 Series
Weight
Chassis only
Chassis fully configured
42 lb (18.9 kg)
88 lb (39.6 kg)
22 lb (9.9 kg)
46 lb (20.7 kg)
Dimensions
22.75 (H) x 19 (W) x 16 (D) inches
(57.78 x 48.26 x 40.64 cm)
10.5 (H) x 19 (W) x 16 (D) inches
(26.67 x 48.26 x 40.64 cm)
Environmental Requirements
Ambient operating temperature
Ambient operating humidity
Ambient storage temperature
Ambient storage humidity
(NEBS GR-63-CORE compliant)
Long term: 41
°
to 104
°
F (5
°
to 40
°
C)
Short term: 23
°
to 122
°
F (-5
°
to 50
°
C)
Long term: 5% to 85% (noncondensing)
Short term: 5% to 95% (noncondensing)
–40
°
to 158
°
F (–40
°
to +70
°
C), 95% relative humidity
5% to 95% (noncondensing)
Heat Dissipation
2400 W, 8190 BTU/hour maximum
1400 W, 4780 BTU/hour maximum
Space Requirements
•
3 feet (90 cm) behind system or
rack
•
No space requirements for sides of
units or rack
•
Do not block air vents on front or
back of the system.
•
3 feet (90 cm) behind system or
rack
•
Do not block air vents on sides of
the system.
•
Do not place equipment that
exhausts hot air to right of the
system.
•
Be aware that system exhausts hot
air from its left side.
•
Allow at least 18 inches (45 cm) at
side of the unit or rack.