Juniper Networks ERX-1410 User Manual
Page 133
Connection Information
ERX Edge Routers
B-11
E3 FRAME
(12 ports)
COCX-F3
E3-12
FRAME
I/O
12
BT43 SMB
(cable that adapts to
75-ohm BNC is
available)
The transmitted signal complies
with
ITUT G.703:
Physical/electrical characteristics
of hierarchical digital interfaces
(November 2001)
for cable
lengths from 0–137 m
(0–450 feet).
FE-2
FE-2
FE-2
I/O
2
RJ-45
•
For 10-Mbps operation, use
CAT 3, 4, or 5 UTP cable.
•
For 100-Mbps operation, use
only CAT 5 UTP cable.
•
The transmitted signal
complies with IEEE
802.3/802.3u for cable
lengths up to 100 m
(328 feet).
FE-8
GE/FE
FE-8
I/O
8
RJ-45
•
For 10-Mbps operation, use
CAT 3, 4, or 5 UTP cable.
•
For 100-Mbps operation, use
only CAT 5 UTP cable.
•
The transmitted signal
complies with IEEE
802.3/802.3u for cable
lengths up to 100 m
(328 feet).
GE
1000 Base-SX
GE/FE
GE
I/O
SFP
a
1 active
1 redundant
LC full duplex
•
Tx power
›
min: –9.5 dBm
›
max: –4 dBm
•
Center wavelength: 850 nm
•
Rx input power
›
min: –17 dBm
›
max: –3 dBm
•
Rated for 275 m (300 yards)
over 62.5-micron core cable
•
Rated for 550 m (601 yards)
over 50-micron core cable
Table B-3 Connection information for module assemblies (continued)
Assembly
Name and
Capability
Line
Module
Label
I/O Module
Label
No. of
Ports
Connector Type
Cabling Specifications