Cabling the srp i/o module, External timing ports, Cabling the srp i/o module -7 – Juniper Networks ERX-1410 User Manual
Page 71: External timing ports -7

Cabling the SRP I/O Module
ERX Edge Routers
4-7
Cabling the SRP I/O Module
The next step in cabling the system is to connect cables to your SRP I/O 
module. See 
Note: The alarm function on the SRP I/O module is currently not implemented.
Cable connections to your SRP I/O module are divided into two sections: 
external timing ports and console ports. 
shows the
specifications for each section.
External Timing Ports
Two external clock source input ports provide a method of ensuring that 
the system’s clock timing remains synchronized with the network’s system 
clock. The primary clock is labeled A; the secondary, redundant clock is 
labeled B. Use the connector type appropriate for your location:
•
Two 75-ohm E1 2.048-Mbps inputs with BNC connectors
•
Two 100-ohm T1 inputs with three pin wire-wrap connectors. Pins are 
labeled T (Tip), G (Ground), and R (Ring). We recommend using 
26-AWG wire minimum.
Note: Use shielded cables to connect the external clock sources to the clock 
source input ports.
Table 4-2 SRP I/O ports
Port
Description
External Timing 
Ports
•
Two 3-pin wire-wrap posts for US external clock sources; 
primary (A) and secondary (B)
•
Two BNC connectors for E1 clock sources; primary (A) and 
secondary (B)
Console Ports
•
One 10/100Base-T Ethernet management port with an RJ-48C 
connector
•
One RS-232 port with a DB-9 connector for VT100 management 
access 