Cable lengths for x.21/v.35 cables – Juniper Networks ERX-1410 User Manual
Page 143

Connection Information
ERX Edge Routers
B-21
Cable Lengths for X.21/V.35 Cables
Serial signals can travel a limited distance without significant
degradation. Slower serial signals can travel farther without degradation
than faster serial signals.
shows the maximum cable lengths
you can use to prevent signal degradation at various transmission speeds.
X.21/V.35
X.21/V.35
X.21/V.35
I/O
16
200-pin proprietary
socket on I/O module
DB15 X.21 or DB34
V.35 at remote end
See
a.The GE SFP I/O module uses a range of simple form factor pluggable transceivers (SFPs) to support different
modes and cable lengths.
b.Assembly is superseded by a newer assembly; however, assembly is supported by current software.
Table B-3 Connection information for module assemblies (continued)
Assembly
Name and
Capability
Line
Module
Label
I/O Module
Label
No. of
Ports
Connector Type
Cabling Specifications
Table B-4 Maximum cable lengths for X.21/V.35 connections
Transmission Speed (Hz) Cable Length (Feet)
Cable Length (m)
2400
4,100
1,250
4800
2,050
625
9600
1,025
312
19200
513
156
38400
256
78
56000
102
31
2048000
25
8