SECTION 6: PARTS SECTION
59
DRAIN QUENCH ASSEMBLY
From the existing drain, attach the two additional Tees using the 1-1/2” NPT Close Nipples. Tighten the Reducers into the Tees
as shown above. Attach the Modified Compression Fitting into the 1-1/2” to 1/4” Reducer. Position the bulb of the thermostat
so that it rests approximately 1/4” from the bottom of the Tee. Tighten the Modified Compression Fitting as required. Attach to
the incoming cold water line. Use pipe dope or thread tape as required to prevent any leaks.
Thermostat
05930-003-13-65
Solenoid Valve
04810-100-09-18
To Cold Water Supply
Nipple, Close, 1/2” NPT
(Not Shown)
04730-207-15-00
Valve, Check, 1/2”
(Not Shown)
04820-002-55-77
Lid, Drain Quench
05700-002-67-16
Box, Drain Quench
05700-002-69-96
Reducer, 1-1/2” to 1/2”
04730-002-55-75
Tee, 1-1/2” x 1-1/2” x 1-1/2”
04730-011-69-93
Modified Compression
Fitting
05700-001-16-52
Reducer, 1-1/2” x 1/4”
04730-002-55-76
To Dishmachine Drain
Nipple, 1-1/2” NPT
04730-207-40-00
Elbow, 1-1/2” 90
B Street
04730-206-32-00
Drain Quench
Assembly
06401-002-59-52