SETUP
SDP-40
3-48
REC PWR ON
LAST LVL, -80 to +6dB
Selects the volume level at which the Record
Zone activates. When a value is selected, the
SDP-40 automatically sets Record Zone
REC PWR ON
VOLUME CONTROLS
SETUP
TRIGGER 1 SETUP
REMOTE ONLY
OFF
DVD1
OFF
DVD2
OFF
LD
OFF
TV
OFF
SAT
OFF
VCR
OFF
CD
OFF
PVR
OFF
GAME
OFF
TAPE
OFF
TUNER
OFF
AUX
OFF
ZONE2 INPUTS
OFF
RECORD INPUTS
OFF
FILM
ON
TV
ON
MUSIC
ON
MUSIC SURR
ON
PLII +
ON
PLII MOVIE
ON
PLII MUSIC
ON
PRO LOGIC
ON
FILM
ON
MUSIC
OFF
NIGHTCLUB
ON
CONCERT HALL
ON
CHURCH
ON
CATHEDRAL
ON
PANORAMA
OFF
PARTY
OFF
2-CHANNEL
OFF
MONO LOGIC
ON
MONO SURROUND
ON
MONO
ON
5.1 FILM
ON
5.1 TV
ON
5.1 MUSIC
ON
5.1 SurEX
ON
5.1 MUSIC
ON
DIGITAL EX
ON
5.1 2-CHANNEL
OFF
5.1 MONO LOGIC
ON
5.1 MONO SURR
ON
5.1 MONO
ON
FILM
ON
MUSIC
ON
ON
MUSIC
ON
ON
2-CHAN
OFF
5.1a FILM
ON
5.1a MUSIC
ON
5.1a SurEX
ON
5.1a MUSIC
OFF
5.1a STANDARD
OFF
5.1a 2-CHANNEL
OFF
5.1a BYPASS
OFF
2CH BYPASS
OFF
R
R
ON
OFF
TRIGGER SETUP
TRIGGER 1
REMOTE
TRIGGER 2
REMOTE
SETUP
INPUTS
SPEAKERS
REAR PANEL CONFIG
DISPLAYS
VOLUME CONTROLS
TRIGGERS
LOCK OPTIONS
TRIGGERS
Record Zone during the previous operating session.
TRIGGER SETUP
Selecting the SETUP menu TRIGGERS option prompts the selection of the desired trigger output connector –
1 or 2. The SDP-40 includes three 12V DC trigger output connectors labeled PWR (power), 1, and 2. The power
connector is not configurable. It is activated when the SDP-40 is activated and deactivated when the SDP-40 is
deactivated. The other connectors can be configured for remote or program operation.
Selecting TRIGGER 1 or TRIGGER 2 opens the corresponding TRIGGER SETUP menu, which can be used to configure
the selected trigger output connector. The TRIGGER SETUP menu shown at the right is used as an example. The
parameters on the left side of the TRIGGER SETUP menus are identical regardless of which connector is selected. The
parameter settings on the right side are adjustable. The TRIGGER SETUP menu shown at the right indicates factory-
default parameter settings for TRIGGER 1. The menu shown on the next page indicates default parameter settings
for TRIGGER 2.
Default
Possible
Parameter
Setting
Settings
REMOTE ONLY
ON
ON, OFF
Program Operation
OFF
ON, OFF
All TRIGGER SETUP menu parameters – except the REMOTE ONLY parameter – are considered program operation parameters.
. . . TRIGGER SETUP continues on page 3-49
TRIGGERS
SETUP
MAIN MENU
MODE ADJUST
AUDIO CONTROLS
SETUP
SETUP
volume level to the selected value when the Record Zone is
activated. When LAST LVL is selected, the SDP-40 sets Record Zone
volume level to the last volume level that was selected in the