Chapter 6. Solving problems
85
00180500
A PCI adapter ROM error occurred.
Action:
Remove the PCI adapters. If you can start the server without the adapters, reinstall
each adapter one at a time and retest after each is reinstalled. When an adapter fails,
replace it.
If you cannot isolate and correct the problem, call for service.
00180600
A PCI-to-PCI bridge error occurred. More than one PCI bus tried to access memory below 1 MB.
Action:
Remove the PCI adapter that has the PCI bridge. If you can start the server without
the adapter, reinstall and retest the adapter. If the adapter fails, replace it.
If you cannot isolate and correct the problem, call for service.
00180700
xxxxyyyy Planar PCI device does not respond or disabled by user. (Where xxxx is the PCI vendor
ID and yyyy is the PCI device ID.)
Action:
Start the Configuration/Setup Utility program, select Devices and I/O Ports, and
make sure that the device is enabled. If the problem persists, call for service.
00180800
An unsupported PCI device is installed.
Action:
Remove the PCI adapters. If you can start the server without the adapters, reinstall
each adapter one at a time and retest after each is reinstalled. When an adapter fails,
replace it.
If the problem persists, call for service.
00181000
PCI error.
Action:
Remove the PCI adapters. If you can start the server without the adapters, reinstall
each adapter one at a time and retest after each is reinstalled. When an adapter fails,
replace it.
If the problem persists, call for service.
01295085
The ECC checking hardware test failed.
Action:
Call for service.
01298001
No update data is available for processor 1.
Action:
Update the system BIOS to a level that supports the microprocessors installed in the
server.
01298002
No update data is available for processor 2.
Action:
Update the system BIOS to a level that supports the microprocessors installed in the
server.
01298101
The update data for processor 1 is incorrect.
Action:
Update the system BIOS to a level that supports the microprocessors installed in the
server.
01298102
The update data for processor 2 is incorrect.
Action:
Update the system BIOS to a level that supports the microprocessors installed in the
server.
01298200
Microprocessor speed mismatch.
Action:
The microprocessors installed do not run at the same speed; install microprocessors
with identical speeds.
I
9990301
A hard disk drive error occurred.
Action:
Call for service.
POST message
Description
Table 13. POST error messages