On

VRM 1 or VRM 2
(system board)

One of the microprocessor VRMs has
failed, or a microprocessor VRM is
installed in the wrong connector.

1. Check the microprocessor VRM

error LEDs on the system board.
If a microprocessor VRM error
LED is on for a microprocessor
VRM connector that has a
terminator card installed instead
of a microprocessor, the
microprocessor VRMs are not
installed in the correct order. See
“Installing and removing a
microprocessor” on page 54
for
information about the correct
order for installing
microprocessor VRMs.
Otherwise, continue with the
next step.

2. Turn off the server, reseat the

microprocessor VRM indicated
by the lit microprocessor VRM
error LED, and restart the server.

3. If the problem persists, replace

the microprocessor VRM.

If the problem persists, have the
system serviced.

On

System error
(front panel)

The diagnostic LEDs have detected a
system error.

1. Check the error LEDs on the

system board to locate the failing
or incorrectly installed
component.

2. Follow the instructions in this

table for replacing the failing
component or removing and
reinstalling the incorrectly
installed component.

If the problem persists, have the
system serviced.

Off

None

The diagnostic LEDs have not
detected a system error.

None

Error LED (on the

system board or

front panel)

System board or
front panel LED

on

Cause

Action

Table 15. Diagnostic LEDs