Chapter 6. Solving problems

93

Microprocessor

Failed

VRM corresponding to Microprocessor in socket xyz
is defective

(where xyz identifies the microprocessor whose VRM
is causing the error message)

Replace the VRM.

If the problem remains,
call for service.

VRM corresponding to Microprocessor in socket id
xyz is not installed

(where xyz identifies the microprocessor whose VRM
is causing the error message)

Install a VRM.

If the problem persists,
call for service.

175

System thermal

Failed

Fan # n

(where n is the number of the failing fan)

Replace the indicated
fan.

Temperature sensed on processor board is out of
range

Call for service.

180

Status display

Failed

Any failure message

Call for service.

201

System memory

Failed

DIMMs in location DIMM n

(where n is the number of the socket that contains the
failing DIMM)

1. Reseat the failing

DIMM.

2. If the problem

remains, replace the
DIMM.

If the problem
persists, call for
service.

Test setup error: Corrupt BIOS in ROM

If your server does not
have the latest level
BIOS installed, update
the BIOS to the latest
level.

If the problem persists,
call for service.

Test setup error: Corrupt DMI BIOS, information in
BIOS is not as expected

Code

Function

Result

Text message

Action