beautypg.com

IBM 220 User Manual

Page 101

background image

Chapter 6. Solving problems

91

035

ServeRAID

Aborted

Test setup error: No ServeRAID adapter found on
system board or PCI bus

Make sure that the
ServeRAID adapter is
properly installed. If the
problem remains,
replace the ServeRAID
adapter. If the problem
persists, call for service.

Failed

Adapter in slot n; adapter/drive configuration error

(where n is the slot number of the failing adapter)

Run the ServeRAID
Configuration Utility.

If the problem remains,
replace the ServeRAID
adapter in slot n.

If the problem persists,
call for service.

Adapter in slot n; internal error

(where n is the slot number of the failing adapter)

Logical drive m on adapter in slot n

(where m is the number of the failing logical drive
and n is the slot number of the adapter)

On system board; internal error

Run the ServeRAID
Configuration Utility.

If the problem persists,
call for service.

On system board; adapter/drive configuration error

Logical drive on system board adapter

Adapter in slot n; memory allocation error

(where n is the slot number of the failing adapter)

Call for service.

On system board; memory allocation error

On system board; PCI configuration error

On system board; POST error

Adapter in slot n; POST error

(where n is the slot number of the failing adapter)

Replace the ServeRAID
adapter in slot n. If the
problem persists, call for
service.

Adapter in slot n; PCI configuration error

(where n is the slot number of the failing adapter)

SCSI drive on adapter in slot n, SCSI ID m

(where n is the slot number of the adapter and m is
the SCSI ID of the drive)

Check the cable and
power connections on
the drive. If the problem
persists, call for service.

075

Power supply

Failed

Voltage sensed by the system is out of range

Call for service.

Code

Function

Result

Text message

Action