IBM 220 User Manual
Page 120
![background image](/manuals/127667/120/background.png)
110
IBM® xSeries 220 User’s Reference
0x02
Explanation:
Bad node address (multicast address).
Action:
Make sure that the locally administered address is valid, if one is specified. The
address can not be a multicast address.
0x03
Explanation:
Failed self-test.
Action:
Make sure a cable is attached to the Ethernet connector. If the problem persists, call
for service.
0x0D
Explanation:
Could not allocate enough memory for transmit queues.
Action:
1. From the Windows NT desktop, select Start -> Control Panel -> Networks -> Adapters.
2. Select your IBM Ethernet adapter from the list.
3. Select Properties -> Advanced.
4. Lower the resource values that apply to the transmit queue.
0x0E
Explanation:
Could not allocate enough memory for receive queue.
Action:
1. From the Windows NT desktop, select Start -> Control Panel -> Networks -> Adapters.
2. Select your IBM Ethernet adapter from the list.
3. Select Properties -> Advanced.
4. Lower the resource values that apply to the receive queue.
0x0F
Explanation:
Could not allocate enough memory for other structures.
Action:
1. From the Windows NT desktop, select Start -> Control Panel -> Networks -> Adapters.
2. Select your IBM Ethernet adapter from the list.
3. Select Properties -> Advanced.
4. Lower the value for the resource named in the message.
0x10
Explanation:
Did not find any Ethernet controllers.
Action:
Using the Configuration/Setup Utility, make sure that Ethernet is enabled.
0x11
Explanation:
Multiple Ethernet controllers found, but none matched the required ID.
Action:
Using the Configuration/Setup Utility, make sure that Ethernet is enabled.
0x13
Explanation:
Did not find any Ethernet controllers that matched the required subven/subdev.
Action:
Using the Configuration/Setup Utility, make sure that Ethernet is enabled.
0x16
Explanation:
Single adapter found but multiple instances tried to load.
Action:
Using the Configuration/Setup Utility, make sure that Ethernet is enabled, and that
the slot containing the IBM Netfinity 10/100 Ethernet Adapter or the IBM 10/100 EtherJet™
PCI adapter is enabled.
0x17
Explanation:
Slot parameter not specified in the registry.
Action:
Remove the adapter driver and reinstall it. If the problem persists, call for service.
All other 4-
character
hexadecimal
codes
Action:
Call for service.
Error code (hex)
Description
Table 19. NDIS (Windows NT or Windows 2000) driver messages for the Ethernet
controller