IBM 220 User Manual

Page 120

background image

110

IBM® xSeries 220 User’s Reference

0x02

Explanation:

Bad node address (multicast address).

Action:

Make sure that the locally administered address is valid, if one is specified. The

address can not be a multicast address.

0x03

Explanation:

Failed self-test.

Action:

Make sure a cable is attached to the Ethernet connector. If the problem persists, call

for service.

0x0D

Explanation:

Could not allocate enough memory for transmit queues.

Action:

1. From the Windows NT desktop, select Start -> Control Panel -> Networks -> Adapters.

2. Select your IBM Ethernet adapter from the list.

3. Select Properties -> Advanced.

4. Lower the resource values that apply to the transmit queue.

0x0E

Explanation:

Could not allocate enough memory for receive queue.

Action:

1. From the Windows NT desktop, select Start -> Control Panel -> Networks -> Adapters.

2. Select your IBM Ethernet adapter from the list.

3. Select Properties -> Advanced.

4. Lower the resource values that apply to the receive queue.

0x0F

Explanation:

Could not allocate enough memory for other structures.

Action:

1. From the Windows NT desktop, select Start -> Control Panel -> Networks -> Adapters.

2. Select your IBM Ethernet adapter from the list.

3. Select Properties -> Advanced.

4. Lower the value for the resource named in the message.

0x10

Explanation:

Did not find any Ethernet controllers.

Action:

Using the Configuration/Setup Utility, make sure that Ethernet is enabled.

0x11

Explanation:

Multiple Ethernet controllers found, but none matched the required ID.

Action:

Using the Configuration/Setup Utility, make sure that Ethernet is enabled.

0x13

Explanation:

Did not find any Ethernet controllers that matched the required subven/subdev.

Action:

Using the Configuration/Setup Utility, make sure that Ethernet is enabled.

0x16

Explanation:

Single adapter found but multiple instances tried to load.

Action:

Using the Configuration/Setup Utility, make sure that Ethernet is enabled, and that

the slot containing the IBM Netfinity 10/100 Ethernet Adapter or the IBM 10/100 EtherJet™
PCI adapter is enabled.

0x17

Explanation:

Slot parameter not specified in the registry.

Action:

Remove the adapter driver and reinstall it. If the problem persists, call for service.

All other 4-
character
hexadecimal
codes

Action:

Call for service.

Error code (hex)

Description

Table 19. NDIS (Windows NT or Windows 2000) driver messages for the Ethernet
controller