Ethernet controller messages

The integrated Ethernet controller might display messages from the following device
drivers:

Novell™ NetWare™ or IntraNetWare Server ODI

NDIS Adapter for level 4.0 (Windows NT)

Novell NetWare or IntraNetWare server ODI
driver teaming messages

This section provides explanations of the error messages for the Novell NetWare or
IntraNetWare server ODI driver, and suggested actions to resolve each problem.

Message

Description

Couldn’t allocate resources

Explanation:

An unknown error has occurred when trying to allocate needed

resources for the AFT Module.
Action:

Check the server configuration. If the problem persists, contact your
network supplier.

Verify that the Ethernet controller is enabled. If the Ethernet controller is
enabled, run the diagnostic programs.

AFT group for primary adapter in slot
nnn already exists.

Explanation:

An attempt was made to rebind an adapter already in an AFT

group.
Action:

Check the AFT slot numbers for existing AFT teams. If the problem

persists, contact your network supplier.

Error locating DCT addresses in
internal table. Make sure that you
have loaded LAN drivers after
loading AFT.NLM.

Explanation:

The bind command was entered prior to loading the device

driver. The device driver must be loaded after loading AFT.NLM but before
any bind command can be issued.
Action:

Load the driver for the supported adapter and try loading the AFT

module again. If the problem persists, contact your network supplier.

Insufficient number of arguments
specified.

Explanation:

The appropriate or expected number of parameters was not

entered in a command.
Action:

Check the parameters required for the given command. If the problem

persists, contact your network supplier.

Duplicate slot numbers detected.

Explanation:

An attempt has been made to bind the same slot number more

than once.
Action:

Check the slot numbers entered during the bind. Adapter slot numbers

must be valid and unique. If the problem persists, contact your network
supplier.

Xxx’ is not supported for AFT team.

Explanation:

A bind command has been issued for adapters not supported by

AFT.NLM.
Action:

Make sure that you attempt to bind only adapters supported by

AFT.NLM.

Primary and Secondary adapters do
not match. AFT group is not created.

Explanation:

A bind command was entered for an adapter team that is a

combination of server and client adapters. An AFT team must be a grouping of
the same classification of adapter.
Action:

Verify that all the adapters bound in a team are of the same

classification.

Table 18. NetWare driver messages for the Ethernet controller