Chapter 6. Solving problems

81

186

A system board or hardware error occurred.

Action:

Call for service.

187

The VPD serial number is not set.

Action:

The system serial number is set in the VPD EEPROM at the time of manufacturing.
If the system board has been replaced, the system serial number will be invalid and
should be set. From the main menu of the Configuration/Setup Utility program,
select System Information, then select Product Data.If the problem persists, call for
service.

188

A vital product data (VPD) error occurred.

Action:

Call for service.

189

An attempt has been made to access the server with invalid passwords. After three incorrect
attempts, the server locks up; that is, the logon data fields are no longer available to the user.

201

An error occurred during the memory controller test. This error can be caused by:

Incorrectly installed memory

A failing memory module

A system board problem

Action:

1. If you just installed memory, verify that the new memory is correct for your

server. Also verify that the memory is installed and seated correctly.

2. If the problem persists, call for service.

229

An error was detected in the L2 cache of one of the microprocessors.

Action:

1. If you just installed a microprocessor, verify that the microprocessor is installed

and seated correctly.

2. If the problem persists, call for service.

289

An error occurred during POST memory tests, and a failing DIMM was disabled.

Note:

You can use the server with decreased memory.

Action:

1. If you just installed memory, verify that the new memory is correct for your

server. Also verify that the memory is installed and seated correctly. Start the
Configuration/Setup Utility program, and select Memory Settings from the
Advanced Setup menu to enable the DIMM.

2. If the problem remains, replace the failing DIMM.

If the problem persists, call for service.

301 303

An error occurred during the keyboard and keyboard controller test. These error messages also
might be accompanied by continuous beeping.

Action:

Ensure that:

1. Nothing is resting on the keyboard and pressing a key.

2. No key is stuck.

3. The keyboard cable is connected correctly to the keyboard and to the correct

connector on the server.

Running the diagnostic tests can isolate the server component that failed, but you must have your
system serviced. If the error message remains, call for service.

Note:

If you just connected a new mouse or other pointing device, turn off the server and
disconnect that device. Wait at least 5 seconds; then, turn on the server. If the error
message goes away, replace the device.

POST message

Description

Table 13. POST error messages