90

IBM® xSeries 220 User’s Reference

Diagnostic error message tables

The following tables provide descriptions of the error messages that might appear
when you run the diagnostic programs.

Attention:

If diagnostic error messages appear that are not listed in the following

tables, make sure that your server has the latest levels of BIOS, ServeRAID, and
diagnostics microcode installed.

Code

Function

Result

Text message

Action

001

Core system

Failed

Processor board, ECC Test

Call for service.

System board

005

Video port

Processor and system boards

011

Serial port

Integrated serial port

014

Parallel port

Integrated parallel port

015

USB interface

Aborted

Can NOT test USB interface while it is in use.

Note:

If you have a USB keyboard or mouse
attached, you cannot run the diagnostic
program for the USB interface.

1. Turn off the server.

2. Replace the USB

keyboard and
mouse with a
standard keyboard
and mouse.

3. Turn on the server.

4. Run the diagnostic

test again.

5. If the test still

aborts with no USB
devices attached,
follow Failed action
below.

Failed

System board

Call for service.

020

PCI interface

Failed

System board

Call for service.

030

SCSI interface

Failed

SCSI adapter in slot n failed register/counter/ power
test

(where n is the slot number of the failing adapter)

Refer to the information
provided with the
adapter for instructions.

If the problem persists,
call for service.

SCSI controller on system board failed
register/counter/power test

Call for service.