beautypg.com

Unresolved problems – IBM B50 User Manual

Page 90

background image

Checkpoint
(hex)

Description

Repair Action

E602

SSA PCI adapter
open firmware has
started.

1. Replace the adapter.
2. See “Unresolved problems” on page 3-26

E603

SSA PCI adapter
BIST has completed
with an error.

1. Replace the adapter.
2. See “Unresolved problems” on page 3-26

E604

SSA PCI adapter
BIST and
subsequent POSTs
have completed
successfully.

1. Replace the adapter.
2. See “Unresolved problems” on page 3-26

E605

SSA PCI adapter
BIST has completed
successfully but the
subsequent POSTs
have failed.

1. Replace the adapter.
2. See “Unresolved problems” on page 3-26

E60E

SSA PCI adapter
open firmware about
to exit (no stack
corruption)

1. Replace the adapter.
2. See “Unresolved problems” on page 3-26

E60F

SSA PCI adapter
open firmware has
run unsuccessfully.

1. Replace the adapter.
2. See “Unresolved problems” on page 3-26

E6FF

SSA PCI adapter
open firmware about
to exit ( with stack
corruption ).

1. Replace the adapter.
2. See “Unresolved problems” on page 3-26

Unresolved problems:

Go to “MAP 1540: Minimum Configuration” on page

2-17 for any of the following conditions:

A 4-digit code in the range of “E100” through “EFFF” is displayed on the operator
panel display but is not listed in the table that lists firmware checkpoints on page
3-14.

A 4-digit code is displayed and is listed in the table that lists firmware
checkpoints on page 3-14, but there are no repair actions or FRUs listed for the
code.

All of the FRUs listed in repair actions have been replaced, and the problem has
not been corrected.

3-26

7046 Model B50 Service Guide