beautypg.com

IBM B50 User Manual

Page 89

background image

Checkpoint
(hex)

Description

Repair Action

E244

Enable system
speaker and send a
beep

Replace system board (see note 3 on page 2-1).

E246

System firmware
corrupted, take
recover path

Replace system board (see note 3 on page 2-1).

E247

Capture DIMM
SPDs into NVRAM

Replace system board (see note 3 on page 2-1).

E249

Enter recover path's
main code

Replace system board (see note 3 on page 2-1).

E24C

L2 cache array test
fails. System hangs.

Replace system board (see note 3 on page 2-1).

E24D

L2 cache array test
fails. System
hangs.

Replace system board (see note 3 on page 2-1).

E298

Take firmware
soft-load path

Replace Softload Image

E299

Start C code
execution.

See “Unresolved problems” on page 3-26

E3xx

Memory test

See “MAP 1240: Memory Problem Resolution” on
page 2-9

E440

Validate nvram,
initialize partitions as
needed

1. Verify that the system firmware is at the current

release level. Update as necessary.

2. See “Unresolved problems” on page 3-26

E441

Generate /options
node nvram
configuration
variable properties

1. Verify that the system firmware is at the current

release level. Update as necessary.

2. See “Unresolved problems” on page 3-26

E442

Validate nvram
partitions

1. Verify that the system firmware is at the current

release level. Update as necessary.

2. See “Unresolved problems” on page 3-26

E443

Generate nvram
configuration
variable dictionary
words

1. Suspect a system firmware problem. If problem

persists, verify that the system firmware is at
current release level. Update downlevel system
firmware.

2. See “Unresolved problems” on page 3-26

E600

SSA PCI adapter
open firmware has
run successfully.

1. Replace the adapter.
2. See “Unresolved problems” on page 3-26

E601

SSA PCI adapter
BIST has been
started but failed to
complete after 4
seconds.

1. Replace the adapter.
2. See “Unresolved problems” on page 3-26

Chapter 3. Error Code to FRU Index